Executive Summary

Seawater Reverse Osmosis (SWRO) desalination systems are highly vulnerable to marine bio-fouling, silt, algae blooms, and suspended solids. A major coastal petrochemical refinery in South America was experiencing rapid fouling of its SWRO membranes due to seasonal red tides and high turbidity in raw seawater intake.

LEFILTER deployed a multi-stage primary filtration architecture comprising LF-BS Series Automatic Multi-Basket Self-Cleaning Strainers combined with heavy-duty Duplex Stainless Steel housings. The system successfully handles a continuous seawater intake flow of 4,500 m³/h, capturing algae, marine debris, and sand down to 150 µm without interrupting raw water delivery. The installation extended downstream ultrafiltration (UF) and RO membrane lifespan by 300%, reduced chemical cleaning frequency from bi-weekly to bi-monthly, and delivered a complete capital payback within 11 months.

Project Background & Industry Pain Points

Located on the Pacific coast of South America, the integrated petrochemical refining complex relies heavily on a 100,000 m³/day SWRO desalination facility to generate high-purity process water, cooling tower makeup water, and boiler feed water. Raw seawater is pumped directly from an open ocean intake channel into the desalination pretreatment building.

Seawater along this coastline contains high concentrations of fine suspended sand, organic debris, shellfish larvae, and seasonal toxic dinoflagellate algae blooms (red tides). The plant’s original intake pretreatment section featured passive manual dual-basket strainers rated at 500 µm.

During seasonal weather shifts and red tide events, raw water Silt Density Index ($SDI_{15}$) spiked dramatically from 3.5 to over 6.8, overwhelming the plant:

Seeking an industrial-grade, corrosion-proof, and fully automated primary seawater filtration system, the refinery’s chief utility engineer partnered with LEFILTER for a complete system overhaul.

保安过滤器_06

LEFILTER Customized Engineering Solution

Recognizing the hyper-corrosive marine environment and the dynamic challenge of seasonal red tides, LEFILTER’s marine engineering department custom-built a 4-vessel parallel system utilizing LF-BS Series Heavy-Duty Automatic Multi-Basket Self-Cleaning Strainers.


1. Super Duplex Metallurgy for Extreme Corrosion Resistance

Because raw seawater contains high chloride concentrations ($>19,000\text{ mg/L}\text{ Cl}^-$) under warm tropical temperatures, conventional 316L stainless steel suffers from pitting and crevice corrosion. LEFILTER fabricated all pressure vessels, internal shaft components, and strainers using Super Duplex Stainless Steel UNS S32750 (2507). This material offers a Pitting Resistance Equivalent Number ($PREN$) exceeding 42, guaranteeing zero localized corrosion over a 20-year design life.

2. Multi-Basket High-Surface Architecture & Wedge Wire Technology

Each LF-BS vessel houses four independently operating wedge wire screen baskets rated at 150 µm.

3. Non-Stop Backwash Mechanism with High-Torque Electric Drives

The LF-BS strainer utilizes an internal rotating suction scanner mechanism driven by a heavy-duty electric motor.

Operational Results & Client Value

Since commissioning over 22 months ago, the LEFILTER LF-BS Seawater Self-Cleaning Filtration Architecture has successfully defended the desalination plant through two severe seasonal red tide cycles: