Compared with the traditional filter, the automatic self-cleaning filter has obvious advantages and avoids some of the disadvantages of the traditional filter. Make it more obvious advantages in various industries. Before using the fully automatic self-cleaning filter, it needs to be installed correctly, and some things need to be paid attention to during installation.
1. First of all, when installing and using, pay attention to the protection of the control box, sensor and transmission parts to prevent damage to the filter;
2. Connect the pipes in the direction indicated by the arrow on the body of the automatic automatic cleaning filter, so that the direction of the water flow can be consistent with the direction of the arrow on the body;
3. The fully automatic self-cleaning filter should be installed before the water equipment that needs to be protected, and it needs to be as close as possible to the water equipment;
4. In the power system, the automatic self-cleaning filter should be installed between the water pump and the water equipment, and the closer it is to the water equipment, the better. When the pressure between the pump and the water equipment exceeds the limit pressure of the filter, the automatic cleaning filter can also be installed in front of the water pump and as close as possible to the water pump;
5. The connection method of the automatic sewage valve can be divided into flange and threaded. The pipe of the sewage pipe should not be too long, preferably not more than 10 meters;
6. When installing the automatic self-cleaning filter, you need to pay attention to make the outlet direction of the automatic sewage valve horizontal or downward to ensure more thorough sewage discharge;
7. The specifications of the automatic self-cleaning filter should match the diameter of the pipe or flow. When a single filter cannot meet the system flow requirements, two or more can be connected in parallel to meet the system filtration requirements;
8. When debugging the electric part of the equipment, please note that the direction of rotation of the motor needs to be consistent with the direction of the mark
9. In use, it is necessary to set the differential pressure according to the actual requirements of the on-site system, so that the sewage can be cleaned and discharged in time;
10. If the pressure difference of the cleaning system cannot be reduced to the set value after repeated cleaning, it should be shut down for maintenance;
11. When the equipment is installed, it should be considered that it can be easily overhauled. The shut-off valve should be installed before and after the automatic self-cleaning filter, and the bypass pipeline should be installed;
12. When the system needs to be manually cleaned and discharged, the control system can be transferred to the manual control unit
                                                                     